1.16i/18i/21i-A/B, Power Mate i-D/H, AND 16/18-C OPERATION B-62924EN/04
- 42 -
Other setting procedure
(Supplement for using the slave function for Power Mate i-D/H)
Procedure using the DPL/MDI operation package (PC)
(1) Press <F4/DGN/PRM>the key to switch between display of the
parameter screen, diagnose screen, pitch error compensation
screen, and Profibus screen. Select the Profibus screen. Then,
Screen 1-11 shown below appears.
Screen 1-11
By displaying Screen 1-11, the parameters (S0001 to S0005) can
be set, and diagnose data (S0101 to S0105) can be displayed.
Table 1-8 Setting parameters
Parameter No. Item Description
S0001 Station NO.
Sets the station number of the DP-
Slave.
S0002
Input Data
Size
Sets the size of DI data.
S0003
Input Data
Address
Sets the address of DI data.
S0004
Output Data
Size
Sets the size of DO data.
S0005
Output Data
Address
Sets the address of DO data.
PROFIBUS
S0002 = R300
S0003 = 16
S0004 = R400
S0005 = 32
S0101 = 00
S0102 = 00
S0103 = 00
>
FANUC Power Mate i DPL/MDI Operation Package
FANUC Power Mate i DPL/MDI Operation PackageFANUC Power Mate i DPL/MDI Operation Package
FANUC Power Mate i DPL/MDI Operation Package
File Edit Disp Help
F1
POS
F2
PRG
F3
MEN
VAR
F4
DGN
PRM
F5
OPR
LM
F6
&@
No.
F7
RD
F8
WRT
F9
HLP
F12F11F10
EXT
S0001 = 3