2.Series 15i-A OPERATION B-62924EN/04
- 76 -
Display procedure
Procedure 1
(1) Press the <SYSTEM> function key several times until the bus
parameter screen, slave parameter screen, or slave function
setting screen appears.
(2) When the bus parameter screen or slave parameter screen
appears, press the soft key [SLAVE SETTING].
Procedure 2
(1) Press the <SYSTEM> function key .
(2) Press the soft key [PROFIBUS-DP].
(3) When the bus parameter screen or slave parameter screen
appears, press the soft key [SLAVE SETTING].
Cursor/paging
1 Use of the cursor keys <↓> <↑> moves the cursor.
• When the cursor key <↓> is pressed in OUTPUT DATA
SIZE, the cursor moves to FDL ADD on the bus parameter
screen.
• When the cursor key <↓> is pressed in STATION NO., the
cursor moves to CONFIG DATA LENGTH on the slave
parameter screen for slave No. 125.
2 Pressing the page key <PAGE ↓> displays the bus parameter
screen.
Pressing the page key <PAGE ↑> displays the slave parameter
screen for slave No. 125.
Initialization
Pressing the soft key [INIT] clears the address assignment parameters.
CAUTION
When assigning addresses, pay careful attention to the
following points:
1 Ensure that the specified DI and DO areas do not
overlap one another.
2 Ensure that specified addresses do not overlap an
area used for a ladder program.
3 Use the R area only. (When using the PMC-SB5, be
careful not to exceed R1499. When using the PMC-
SB6 or the PMC-NB6, be careful not to exceed
R2999.)