3.Power Mate-D/H OPERATION B-62924EN/04
- 88 -
3.1 SLAVE FUNCTION SETTING
Procedure using the CRT/MDI
(1) Press function key <SYSTEM>, then press soft key
[PARAMETER] to display the parameter screen of the Power
Mate-D/H.
(2) Set the parameters described below in the same way as for
ordinary parameters.
(3) With the slave function of the Power Mate-D/H, the PMC
addresses used for DI/DO input are X1032 and up, and the PMC
addresses used for DI/DO output are Y1032 and up at all times.
An area of the size specified in each parameter is used.
Parameters
0171 DI data size
[Data type] Word
[Unit of data] Word
[Valid data range] 1 to 32
This parameter specifies the size of DI data to be transferred to and
from the DP-Master, by using the number of bytes.
0172 DO data size
[Data type] Word
[Unit of data] Word
[Valid data range] 1 to 32
This parameter specifies the size of the DO data to be transferred to
and from the DP-Master, by using the number of bytes.
0173 Station number of the DP-Slave
[Data type] Word
[Unit of data] Word
[Valid data range] 1 to 125
This parameter specifies the station number of the DP-Slave.
Procedure using the DPL/MDI
(1) Press the <DGNOS/PARAM> key to switch to the parameter
screen of the Power Mate-D/H.
(2) Set the parameters described earlier in the same way as for
ordinary parameters.