08
[[Data type] Word
[Unit of data] V
[Valid data range] 0~32767
Specify power setting 0 to 8 at the table intervals, in the indicated order, when
half of the discharge tubes are used. For the standard setting, refer to the sheet
attached to the laser oscillator.
29048
Upper limit on power(Fine mode)
[[Data type] Word
[Unit of data] W
[Valid data range] 0~32767
When the specified power value exceeds this setting after power calibration and
power feedback addition, the actual power is clamped to this setting.
29049
Maximum peak power(Fine mode)
[[Data type] Word
[Unit of data] W
[Valid data range] 0~7000
When a peak power higher than this setting is specified, the actual power is
clamped to this setting. (The value obtained by applying power override is
clamped.)
29050
Upper limit on power when the duty ratio is not clamped(Fine mode)
[[Data type] Word
[Unit of data] W
[Valid data range] 0~7000
When the duty ration is not clamped to 50% according to parameter NO.29051
and when the specified power exceeds this setting after power calibration and
power feedback addition, the actual power is clamped to this setting. When 0 is
specified, the value of parameter No.29048 is assumed.
29051
Criterion for clamping the duty ratio(Fine mode)
[[Data type] Word
[Unit of data] W
[Valid data range] 0~7000
Ed.
Apprv.Design
Date
Design
Descri
tion
FANUC Series 16i /160i –LB
Processing mode change function
-90107E
Sep.17,2005
H.Tokito
10
19
Title
Draw
No.
Sheet
07
06
05
04
03
02