Laser pwer in aging(Fine mode)
[[Data type] Word
[Unit of data] W
[Valid data range] 0~7000
Set the power to be specified when aging is performed by the automatic aging
function.
29067
Oscillation frequency in aging(Fine mode)
[[Data type] Word
[Unit of data] Hz
[Valid data range] 5~2000
Set the frequency to be specified when aging is performed by the automatic aging
function.
29068
Pilse duty ration in aging(Fine mode)
[[Data type] Word
[Unit of data] %
[Valid data range] 0~100
Set the pulse duty ration to be specified when aging is performed by the
automatic aging function.
29069
Calibration time in aging(Fine mode)
[[Data type] Word
[Unit of data] sec
[Valid data range] 0~32767
Set the time to be specified per operation when aging is performed by the
automatic aging function.
29070
Gas pressure in aging(50Hz)(Fine mode)
[[Data type] Word
[Unit of data] (1=13Pa)
[Valid data range] 0~32767
Ed.
Apprv.Design
Date
Design
Descri
tion
FANUC Series 16i /160i –LB
Processing mode change function
-90107E
Sep.17,2005
H.Tokito
14
19
Title
Draw
No.
Sheet
07
06
05
04
03
02
Set the in-tube pressure to be set during oscillation when aging is performed by
the automatic aging function. For an oscillator containing an inverter, set the
same value as the setting of parameter No.29071. (The value set when an