08
- Discharge start ready signal
LRDY<F221#1>
[Classification] Output signal
[Function] This signal notifies the PMC that the CNC is ready for discharge for the
oscillator.
[Operation] When the discharge start ready signal (LRDY) is set to 1, the CNC can accept the
discharge start signal (HVON).
The discharge start ready signal becomes 1 under the following condition:
• When the oscillator start signal (RUN) is set to 1, and the CNC is ready for
discharge.
• When the discharge start signal (HVON) is set to 0 during oscillation.
• When the oscillator start signal (RUN) is set to 0 during oscillation.
• When emergency stop is performed during oscillation.
The signal becomes 0 under the following conditions:
• When the discharge start signal (HVON) is set to 1 while the discharge
start ready signal (LRDY) is set to 1.
• When the oscillator start signal (RUN) is set to 0 while the discharge start
ready signal (LRDY) is set to 1.
- Oscillator signal
LSTR<F221#6>
[Classification] Output signal
[Function] This signal notifies the PMC that the CNC is ready for output.
[Operation] When the oscillator signal (LSTR) is set to 1, laser output can be specified for
machining.
The LSTR signal becomes “1” under the following condition:
• When the oscillator enters the reference discharge state.
The LSTR signal becomes “0” under the following condition:
• When the discharge start signal (HVON) becomes 0.
• When the oscillator start signal (RUN) becomes 0.
• When a laser alarm occurs.
• When an emergency stop occurs.