setting. And displayed items of aging function are also changed in the aging
function setting screen. In case of parameter No.15014#4(MAG)=1, all the pages
of aging setting screen are displayed. At that time, the items displayed in page 2
and page 3 are changed to those for High power mode or for Fine mode by
processing mode setting. Which setting values are displayed is indicated on the
automatic aging setting screen.
・Laser gas monitor
In the laser oscillator start up sequence, alarm No.4125 happens if DCI value of
laser power supply is equal to or higher than parameter No.29047 when in-tube
pressure reaches parameter No.29046 after HVON(G222#7)=1. This alarm shows
that the composition (mixture) of laser gas is not correct for set processing mode.
When this alarm happens, oscillator stop sequence is started and laser oscillator
returns to PURGE state.
This alarm is monitored just only one time even if laser oscillator start up
sequence is repeated by automatic aging function or warm up function.
Alarm No.4125 can’t be monitored if parameter No.29046, No.29047 or
No.15008#5 is “0”.
3. Parameters
・Settings for laser oscillator
(Fine mode)
#7 #6 #5 #4 #3 #2 #1 #0
29016 CCM CTA
[Data type] Bit
CTA The processing mode of laser oscillator is :
0: High power mode.
1: Fine mode.
CCM Processing mode change function is :
0: Not available.
1: Available.
Note
Parameter CTA can't be turned on when parameter CCM is off. Even if
CTA is set to “1” in case of CCM=0, the setting of CTA returns to zero.
If parameter CCM is turned off in case of CTA=1, CTA returns to zero
and thus processing mode is changed. To prevent unexpected
operation, parameter CCM should be set when laser oscillator is in
PURGE state. Don’t set parameter CCM except for PURGE state
Ed.