FANUC Series 16i-TA
2 CPU 3-path control function
Specifications
A-63406E
08 00.09.01 T.Nakazato Modified (viii)
07 00.06.23 T.Nakazato Modified (vii) H. kochiya
01 97.04.09 T.Nakazato Newly registered T. Masuda
ED. DATE DESIG. DESCRIPTION
TITLE
DRAW.NO.
SHEET
7 6 5 4 3 2 1 0
8162 MUMx MCDx MPSx MPMx OMRx PKUx SERx SMRx
[Data type] Bit axis
SMRx Synchronous mirror-image control is:
0: Not applied. (The master and slave axes move in the same direction.)
1: Applied. (The master and slave axes move in opposite directions.)
SERx The synchronization deviation is:
0: Not detected.
1: Detected.
PKUx In the parking state,
0: The absolute, relative, and machine coordinates are not updated.
1: The absolute and relative coordinates are updated. The machine coordinates
are not updated.
OMRx Superimposed mirror-image control is;
0: Not applied. (The superimposed pulse is simply added.)
1: Applied. (The inverted superimposed pulse is added.)
MPMx When composite control is started, the workpiece coordinate system is :
0: Not set automatically.
1: Set automatically.
MPSx When composite control is terminated, the workpiece coordinate system is:
0: Not set automatically.
1: Set automatically.
MCDx The axes to be replaced with each other under composite control have the
coordinate systems placed:
0: In the same direction. Simple composite control is applied. (The axes of paths
1 and 2 move in the same direction.)
1: In opposite directions. Mirror-image composite control is applied. (The axes
of paths 1 and 2 move in opposite directions.)
This parameter determines the direction in which an axis moves. The parameter
is also used to automatically set the coordinate system when composite control is
started or terminated.
MUMx In composite control, a move command for the axis:
0: Can be specified.
1: Cannot be specified.