FANUC Series 16i-TA
2 CPU 3-path control function
Specifications
A-63406E
08 00.09.01 T.Nakazato Modified (viii)
07 00.06.23 T.Nakazato Modified (vii) H. kochiya
01 97.04.09 T.Nakazato Newly registered T. Masuda
ED. DATE DESIG. DESCRIPTION
TITLE
DRAW.NO.
SHEET
8190 Rapid traverse rate of an axis under superimposed control
[Data type] Two-word axis
[Unit of data]
[Valid data range]
Valid data range
Increment system Unit of data IS-A,IS-B IS-C
Millimeter machine 1 mm/min 30 to 240000 30 to 100000
Inch machine 0.1 inch/min 30 to 96000 30 to 48000
Rotation axis 1 deg/min 30 to 240000 30 to 100000
Set a rapid traverse rate for each of the axes when the rapid traverse override of
the axes (master and slave axes) under superimposed control is 100%.
8191
F0 velocity of rapid traverse override of an axis under superimposed control
[Data type] Word axis
[Unit of data]
[Valid data range]
Valid data range
Increment system Unit of data IS-A,IS-B IS-C
Millimeter machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 600 6 to 4800
Rotation axis 1 deg/min 6 to 15000 6 to 12000
This parameter specifies the F0 velocity of rapid traverse override for each of the
axes (master and slave axes) under superimposed control.
8192
Linear acceleration/deceleration time constant in rapid traverse of an axis
under superimposed control
[Data type] Word axis
[Unit of data] ms
[Valid data range] 0 to 4000
This parameter specifies the linear acceleration/deceleration time constant in
rapid traverse for each of the axes (master and slave axes) under superimposed
control.