FANUC Series 16i-TA
2 CPU 3-path control function
Specifications
A-63406E
08 00.09.01 T.Nakazato Modified (viii)
07 00.06.23 T.Nakazato Modified (vii) H. kochiya
01 97.04.09 T.Nakazato Newly registered T. Masuda
ED. DATE DESIG. DESCRIPTION
TITLE
DRAW.NO.
SHEET
7 6 5 4 3 2 1 0
8163 SCDx SCMx SPSx SPMx MDXx
[Data type] Bit axis
MDXx In composite control, the current position (absolute/relative coordinates) display
indicates:
0: Coordinates in the local system.
1: Coordinates in the other system under composite control.
SPMx When synchronous control is started, automatic workpiece coordinate system
setting for the master axis is:
0: Not performed.
1: Performed.
SPSx When synchronous control terminates, automatic workpiece coordinate system
setting for the master axis is:
0: Not performed.
1: Performed.
SCMx When workpiece coordinates are calculated in synchronous control:
0: The workpiece coordinates are calculated from the machine coordinates of
the slave axis.
1: The workpiece coordinates are calculated from the machine coordinates of
the master axis and slave axis.
SCDx The positive (+) directions of the master axis and slave axis in the coordinate
system in synchronous control are:
0: Identical.
1: Opposite.
Parameter SPMx,SPSx,SCMx, and SCDx must be specified for the master axis.
These parameter settings are referenced in synchronous control begins.