(7) Alarms and messages
No. Message Description
160 MISMATCH WAITING M-CODE
(a) The commands have identical P values
but different M codes.
(b) The commands have identical M codes
but different P values.
(c) Both two-path and three-path wait are
simultaneously executed.
161 ILLEGAL P OF WAITING
M-CODE
(a) The address P value is negative, 1, 2, 4,
or a value greater than 8.
(b) The specified P value conflicts with the
system configuration.
An alarm causes a single-block stop to occur, causing the path to enter the automatic operation