B–63083EN/02
9. CONNECTION TO FANUC I/O Link
143
(Address)
The start address of X (DI) of the basic modules including the analog input
module must always be allocated at an even–numbered address. With this
allocation, the digital output addresses of the analog input module are as
described below, depending on where the analog input module is
allocated
D When the analog input module is allocated in the space for expansion
module 1 (m represents the allocation start address.)
7
UndefinedXm+3 (odd–numbered address)
D07
6
D06
5
D05
4
D04
3
D03
2
D02
1
D01
0
D00Xm+4 (even–numbered address)
Address in the module
0 0 CHB CHA D11 D10 D09 D08Xm+5 (odd–numbered address)
D When the analog input module is allocated in the space for expansion
module 2 (m represents the allocation start address.)
7
UndefinedXm+8 (even–numbered address)
D07
6
D06
5
D05
4
D04
3
D03
2
D02
1
D01
0
D00Xm+6 (even–numbered address)
Address in the module
0 0 CHB CHA D11 D10 D09 D08Xm+7 (odd–numbered address)
D When the analog input module is allocated in the space for expansion
module 3 (m represents the allocation start address.)
7
UndefinedXm+9 (odd–numbered address)
D07
6
D06
5
D05
4
D04
3
D03
2
D02
1
D01
0
D00Xm+10 (even–numbered address)
Address in the module
0 0 CHB CHA D11 D10 D09 D08Xm+11 (odd–numbered address)
NOTE
When two–byte digital output addresses are to be
referenced with a PMC program, a read must always be
performed word–by–word (16 bits).