B–63083EN/02
3. INSTALLATION
19
Unit Power Consumption (W)
Series 21i control unit without
option slot
33 W including LCD and MDI unit.
Series 21i control unit with option
2 slots
37 W including LCD and MDI unit.
Series 210i control unit
(with PC functions)
without option slot
45 W including LCD, MDI unit, hard disk
drive and floppy disk drive.
Series 210i control unit
(with PC functions)
with option 2 slots
52 W including LCD, MDI unit, hard disk
drive and floppy disk drive.
Option board
(Remote buffer, DNC1, DNC2)
6 W
Loader control board 10 W
HSSB board 3 W
PMC C language board 6 W
Symbol CAPiT board 10 W
ISA extension (Note 2)
Separate detector interface unit 9 W (Note 4)
PC interface connector panel unit 0 W
NOTE
1 For other peripheral devices (I/O, etc.), see the heat
dissipation data for each device and add the value to the
above.
2 As this value varies depending on the ISA board being
used, add the dissipation value for the installed ISA board.
3 The heat dissipation of the Series 210i control unit with
HSSB is identical to the sum of that of the Series 21i control
unit and that of the HSSB board.
4 Not including the heat dissipation of the separate detector
itself.
3.4.3
Heat Dissipated by
Each Unit