I. MAINTENANCE WITH DISPLAY
LINK TYPED TOUCH PANEL
B–63175EN/03
APPENDIX
656
In this chapter, the CNC maintenance operation at power–on is described.
According to the operation on the LCD with touch screen, the following
maintenance operation can be performed.
D Bootstrap system operation
– Load the system file from a memory card to the Flash ROM.
(System file: touch panel application, ladder application,
C–language executor application etc.)
– Confirm the edition of the system file.
– Delete the system file in the Flash ROM.(user’s file)
– Backup the system file in the Flash ROM into a memory
card.(user’s file)
– Backup/restore the data in SRAM area.
– Delete a file in a memory card.
– Format memory card.
D CNC initializing operation
– Clear all memory.
– Clear CNC parameters and offset data.
– Clear all programs.
– Clear PMC parameters.
– Clear PMC ladder.
– Reset OT alarm.
– Start the system without ladder running.
I.3
MAINTENANCE
OPERATION AT
POWER–ON