B–63175EN/03
1. DISPLAY AND OPERATION
67
Reset
Function
KEY
SW
SETTING
PWE=1
Mode
Function
key
Operation
Resetting the operating time _ POS [(OPRT)] [TIME: 0] → [EXEC]
Resetting the number of
machined parts
_ POS [(OPRT)] [TIME: 0] → [EXEC]
Resetting the OT alarm When the
power is on
_
P CAN
CRT/MDI
and
LCD with touch panel
Turn on the power while holding down
the top–right corner of the screen.
Display the IPL screen, then
P → [SELECT] → [YES]
CAN → [SELECT] → [YES] → [YES]
Resetting alarm 100 _ _
RESET
CAN
CRT/MDI
and
LCD with touch panel
SPCL → CAN → RESET →
ENTER
Data input from the MDI
Function
KEY
SW
SETTING
PWE=1
Mode
Function
key
Operation
Inputting parameters f MDI or
emergency stop
SYSTEM
(PARAM)
Parameter No. → [NO.SRH] → Data
→ INPUT → PWE = 0 →
INPUT
RESET
Inputting offset data OFF _ OFFSET Offset No. → [NO.SRH] → Offset
value → INPUT
Inputting setting data OFF MDI SETTING
Setting No. → [NO.SRH] → Data → INPUT
Inputting PMC parameters
(for the counter and data table)
OFF MDI or
emergency
stop
SYSTEM
(PMC)
[PMCPRM] → [COUNTR] → Data
[DATA]
→
INPUT
Inputting PMC parameters
(for the timer and keep relay)
f
[PMCPRM] → [TIMER] → Data →
[KEEPRL]
INPUT
Tool length compensation JOG POS →
OFFSET
POS (Display of relative coordinate system)
AXIS → [ORIGN] → OFFSET →
More the tool measuvment position
Offset No. → [NO.SRH] → AXIS → [C INPUT]
1.9
LIST OF
OPERATIONS
(SETTING AND
DISPLAY UNIT (CRT,
PDP, LCD, HANDY
OPERATOR’S PANEL,
AND LCD WITH
TOUCH PANEL))