Table. (c) Example of setting parameters related to acceleration pattern
Parameter
No.
Setting Unit Remarks
Rapid
traverse
rate
1420 48000. mm/
min
The ball screw pitch is assumed 16
mm, so that the rapid traverse rate
is 48000 mm/min at the maximum
speed 3000 (min
).
1−
Referen
ce
acceler
ation
1773
194 msec Reference acceleration is
= 4124 (mm/sec
2
)
Speed
at P1
19541 515
.01
%
- In the case that the parameter
No.1774 (Time constant for
bell-shaped accel/deceleration)
has a value, for example,
40(msec), the Speed at P1 is
2474mm/min with the
calculation in the previous
page. Accordingly, 5.15%, the
ratio to Rapid traverse rate is
set. 0.0515=2474/48000
- In the case that the parameter
No.1774 has the value 0, a
value of about 5.00% is set.
Speed
at P2
19542 6666
.01
%
66.66% is set at P2 because the
torque 90(Nm) is constant up to
2000 (min ) (32000mm/min).
1−
0.6666=32000/48000
Speeds
at P3 to
P4
19543 to
19544
0
.01
%
P3 to P4 are skipped because the
torque drops almost linearly from the
speed 2000 (min ) to 3000
(min
).
1−
1−
Acceler
ation at
P0
19545,19551
19557,19563
18712
.01
%
Set 1/2 of Acceleration at P1, 9356.
Acceler
ation at
P1
19546,19552
19558,19564
18712
.01
%
At P1, 90(Nm) can be used for the
acceleration/deceleration, so set the
ratio 7717 (mm/sec
2
) to 4124
(mm/sec
2
).
1.8712 = 7717/4124
Acceler
ation at
P2
19547,19553
,19559,1956
5
18712
.01
%
Set the same value with P1
Acceler
ation at
P3 to
P4
19548,19549
19554,19555
19560,19561
19566,19567
0
.01
%
0 is set because P2 to P4 are
skipped.
Acceler
ation at
P5
19550,19556
19562,19568
14345
.01
%
At P5, 69(Nm) can be used for the
acceleration/deceleration, so set the
ratio 5916 (mm/sec
2
) to 4124
(mm/sec
2
).
1.4345 = 5916/4124
48000/60
194/1000
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
8/15
PAGEEDT.
DATE
DESIGN
DESCRIPTION
TITLE
No.
FANUC Series 16i/18i/160i/180i/160is/180is-MA
OPERATOR’S MANUAL
Concerning the addition of
Optimum Torque acceleration/deceleration
B-63014EN/02-9
01 02.07.29 Newly Registered