2.6. Application Control Signals
2.6.1. Application RUN / STOP Status
The PMC control of the application to go to the RUN- or STOP-Status.
#7 #6 #5 #4 #3 #2 #1 #0
D-Base
Addr + 3
ARSS
[Direction] from PMC to Macro Executor Application Program
[Data Type] Bit [ARSS] Status: Application Run Stop Status
0: The PMC requested the application to go to the STOP Status.
1: The PMC requested the application to go to the RUN Status.
Note: In case of application STOP Status the control of the P-Code Variable Screen display
“enable/disable” is still active.
2.6.2. Alarm Messages displayed or not displayed
The PMC control of the application to open the MESSAGE-SCREEN or not in case of an application alarm.
#7 #6 #5 #4 #3 #2 #1 #0
D-Base
Addr + 3
AMDS
[Direction] from PMC to Macro Executor Application Program
[Data Type] Bit [AMDS] Status: Alarm Message Display Status
0: In case of an application alarm it doesn’t open automatically the alarm screen.
1: In case of an application alarm it does open automatically the alarm screen.
Note: In case of the alarm “NOT ALL TOOL POSTS MEASURED” the MESSAGE-SCREEN will
be opened always and not in dependence of the control-bit “AMDS”.
——————————————————————————————————————