GE Fanuc Automation
Version: 4
GFTE-557E-EN
2.3. Active or selected Tool-Post Number
The PMC informed the application about the active or selected Tool Post Number.
#7 #6 #5 #4 #3 #2 #1 #0
D-Base
Addr + 1
TP4 TP3 TP2 TP1 TP0
[Direction] from PMC to Macro Executor Application Program
[Data Type] 5 Bits [TP0…TP4] Active Tool Post Number of Turret
Tool-Post-No TP4 TP3 TP2 TP1 TP0
No Tool Post 0 0 0 0 0
1 0 0 0 0 1
2 0 0 0 1 0
:
:
:
31 0 1 1 1 1
32 1 0 0 0 0
In case the selected Tool Post Number is zero or greater than the quantity of Tool Post (QP0...QP4)
an alarm will be generated.
2.4. Offset Value Measurement B Signals (Probe Touch Signals)
The PMC informed the application about the actual selected Probe Touch Signals.
#7 #6 #5 #4 #3 #2 #1 #0
D-Base
Addr + 2
MC-Z MC+Z MC-X MC+X
[Direction] from PMC to Macro Executor Application Program
[Data Type] Bit [MC+X, MC-X, MC+Z, MC-Z] Status: Measurement Contact Signal
0: The Tool Measurement Process Contact Signal isn’t detected.
1: The Tool Measurement Process Contact Signal is detected.
The status signals are related to the following PMC signals:
MC+X +MIT1 (+MITX): Contact to X-axis (X + direction) contact face
MC-X -MIT1 (-MITX): Contact to X-axis (X - direction) contact face
MC+Z +MIT2 (+MITZ): Contact to Z-axis (Z + direction) contact face
MC-Z -MIT2 (-MITZ): Contact to Z-axis (Z - direction) contact face
In case more than one signal are selected an alarm will be generated and the measurement will be
suppressed.
——————————————————————————————————————
In case a supported axis is selected and the incoming touch signal is related to another axis an alarm will be
generated and the measurement will be suppressed.
Sauter-Turret and
2
nd
Geometry Tool Data
6.0
28
th
January 2003