B–63523EN–1/02
1. AXIS CONTROL
121
When the coordinate system actually set by the G92 (G50) command or
the automatic coordinate system setting deviates from the programmed
workpiece coordinate, the set coordinate system can be shifted.
Set the desired shift amount in the workpiece coordinate system shift
memory.
X–Z: Coordinate system in programming
x–z: Current set coordinate system with shift
amount 0
(coordinate system to be modified by
shifting)
Set the shift amount from O’ to O in the workpiece coordinate system shift memory.
x
X
Z
z
O
O’
Shift
Workpiece Coordinate System shift
Besides the six workpiece coordinate systems (standard workpiece
coordinate systems) selectable with G54 to G59, 48 or 300 additional
workpiece coordinate systems (additional workpiece coordinate systems)
can be used.
#7 #6 #5 #4 #3 #2 #1 #0
1201 AWK ZPI ZPR
[Data type] Bit
ZPR Automatic setting of a coordinate system when the manual reference
position return is performed
0 : Not set automatically
1 : Set automatically
NOTE
If a workpiece coordinate system option is available,
automatic coordinate system setting is not performed.
Whenever manual reference position return is performed,
the workpiece coordinate system is established according
to the workpiece origin offset (parameter Nos. 1220 to
1226).
Workpiece coordinate
system shift (T series)
Addition of workpiece
coordinate system pair
(M series)
Parameter