14. MEASUREMENT
B–63523EN–1/02
1686
#7
3003
#6 #5 #4 #3
DIT
#2 #1 #0
[Data type] Bit
DIT Interlock for each axis direction
0 : Enabled
1 : Disabled
#7
5004
#6 #5 #4 #3
TS1
#2 #1 #0
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
TS1 When the tool offset measurement value direct input B function is used,
touch sensor contact detection is based on:
0 : Four–contact input.
1 : One–contact input.
#7
5005
#6 #5
QNI
#4 #3 #2 #1 #0
[Data type] Bit
QNI The function to input offset value measured B
0 : Does not automatically select the tool offset number
1 : Automatically selects a tool offset number
#7
5009
#6 #5 #4 #3 #2 #1 #0
GSC
[Data type] Bit
GSC Specifies from which the offset write input signal is to be input for the tool
compensation amount measurement value direct input B function, as
follows:
0 : To be input from the machine.
1 : To be input from the PMC.
NOTE
1 After setting this parameter, turn the power off then on again
so that the setting will take effect.
2 If axis direction–specific interlock is enabled (bit 3 or
parameter No. 3003 (DIT) is 0), its input is also switched
from the machine to the PMC.
Parameter