GE Fanuc Automation
Version: ii
GFTE-557E-EN
This document shouldn’t be distributed to the end-user!!
Sauter-Turret and
2
nd
Geometry Tool Data
Title of Document Sauter-Turret and 2
nd
Geometry Tool Data
Document – Summery
6.0
Document-Version: 6.0
28
th
January 2003
Last Change: 28
th
January 2003
Start of Edition: 02
nd
September 2002
Printed Date: 04/12/2003
Author: Peter Mosebach
File-Name: Sauter-Turret.pdf
Total Pages 85
Version-History
Version Date Sign Description
1.0 04/09/02 PGM first Edition
2.0 04/09/02 PGM Correction of Chapter 2.2 on Page 2
3.0 08/10/02 PGM Correction of Specification
4.0 05/11/02 PGM Final Review of the Specification
6.0 29/11/02 PGM Availability of Function A-76508EN
6.0 28/01/02 PGM Review after first Test at the Customer
6.0 04/12/03 PGM Change Document-Number
GFTE-557-EN to GFTE-557E-EN
Correction of Date
28
th
January 200 to 28
th
January 2003
Why a new Edition of Specification:
We found with the first test at the customer, that the pressed soft-key doesn’t always generate a correct
measurement trigger signal. The application software works fine in case the operator doesn’t make any input
fault and if yes the measurement of the tool post or tool was wrong what is a danger situation.
The software edition 2 take care of the operators input action and value and with this feature a correct
measurement is provide always.
——————————————————————————————————————