7
7.2 Parameter List
258
1) For setting (These parameters can be set at “Setting screen”.)
00000
Setting
#0 TVC : TV check is not performed (0)/performed (1)
#1 ISO : Data output by EIA code (0)/by ISO code (1)
#2 INI : Input increment by mm (0)/by inch (1)
#5 SEQ : Automatic insertion of sequence No. is, not
performed (0)/performed (1)
PRM3216
00001 Tape format
#1 FCV : FS16 standard (0)/FS15 Tape format (1)
00002 Reference position returns, remote diagnosis
#0 RDG : Remote diagnosis is, not performed
(0)/performed (1)
This param-
eter need
not be set
when a mo-
dem card is
used
#7 SJZ : For manual reference position return,
deceleration dogs are used when a reference
position is not established, and positioning is
performed when a reference position is
established (0)/deceleration dogs are used at
all times (1)
M series
PRM
1005#3=1
00012 Axis detaching, movement command, mirror
image
<Axis>
#0 MIR : Setting of mirror image for each axis is OFF
(0)/ON (1)
#4 AIC : An axis–specified travel distance, follows a
specified address (0)/is incremental at all times
(1)
#7 RMV : Detach of the each axis is not performed (0)/
performed (1)
PRM
1005#7
T series