7
7.2 Parameter List
260
2) For reader/puncher interface
00100
Common to each channel
#1 CTV : TV check in the comment section of a program
is performed (0)/not performed (1)
#2 CRF : When an EOB is output by ISO code, the
setting of PRM100#3 (NCR) is followed (0)/CR
and LF are used (1)
#3 NCR : When output EOB by ISO code, LF, CR, CR
(0)/CR output (1)
#5 ND3 : DNC operation is performed to read blocks
one by one (0)/until the buffer becomes full (1).
#6 IOP : Input/output of an NC program is stopped by
resetting the CNC (0)/by pressing the [STOP]
soft key (1).
#7 ENS : Reading of data by EIA code, if NULL code is
red in the data, ignore it (0)/make alarm (1)
ALM001
00101 Parameter relating to CHANNEL 1
(I/O CHANNEL=0)
#0 SB2 : Number of stop bit is 1 bit (0)/2 bits (1)
#1 HAD : The alarm issued on a built–in Handy File, is
ALM86 (0)/provides a detail indication (1)
#3 ASI : Data input by EIA or ISO code (0)/ASCII code
(1)
#7 NFD : FEED before & after of data is output (0)/not
output (1)
M series
00102 Spec. No. of I/O devices of CHANNEL 1
(I/O CHANNEL=0)
0 : RS-232-C (Used control codes DC1 to DC4)
1 : CASSETTE B1/B2 (Bubble cassette)
2 : FLOPPY CASSETTE ADAPTER F1
3 : PROGRAM FILE Mate, FA Card, FSP-H,
FLOPPY CASSETTE, Handy File
4 : RS-232-C (Control codes DC1 to DC4 are not
used.)
5 : PORTABLE TAPE READER
6 : PPR, FSP-G, FSP-H
00103 Baud rate setting of CHANNEL 1
(I/O CHANNEL=0)
1 : 50 bps 7 : 600 bps
2 : 100 bps 8 : 1200 bps
3 : 110 bps 9 : 2400 bps
4 : 150 bps 10 : 4800 bps
5 : 200 bps 11 : 9600 bps
6 : 300 bps 12 : 19200 bps
00110 Separate control of I/O channel number
#0 IO4 : Separate control of I/O channel numbers is,
not performed(0)/performed(1)
PRM20
to 23
l