19
19.1 Inputting/Outputting Data
892
8. Press soft key then key .
9. Press soft key [I/O] and set the parameters on I/O.
Item selection cursor moves to the following item after data of an item
is set.
10. In CHANNEL NO item, input
1
INPUT
to select I/O channel 1.
11. In DEVICE item, press soft key [FDCAS] to select the floppy cassette.
12. In KIND DATA item, press soft key [PARAM].
13. In FUNCTION item, press soft key [WRITE].
14. In FILE No item, specify a file name. In this example input as follows:
@
M C
INPUT
15. Press soft key [EXEC]. Then PMC parameters are started to be output.
16. After the PMC parameters have been output, set PARAMETER WRITE
to 0.
17. Press
RESET
to release alarm 100.
19.1.2.3 Outputting pitch error compensation amount
1. Select EDIT mode.
2. Press
SYSTEM
key several times, press soft key [PARAM], and
[PITCH] to select the SETTING screen for pitch error amount.
3. Press soft key [(OPRT)] and .
4. Press soft key [PUNCH] and [EXEC], then pitch error compensation
amount is started to be output.
19.1.2.4 Outputting custom macro variable values
When custom macro function is equipped, values of variable No. 500 and
later are output.
1. Press
SETTING
OFFSET
key.
2. Press
key and soft key [MACRO] to select custom macro variable
screen.
3. Press soft key [(OPRT)] and then key
.
4. Press soft key [PUNCH] and [EXEC], then custom macro variable
values are output.
19.1.2.5 Outputting compensation (tool compensation amount)
1. Select EDIT mode.
2. Press
SETTING
OFFSET
key and soft key [OFFSET] to display the tool
compensation amount screen.
3. Press [(OPRT)] key and soft key .
4. Press soft key [PUNCH] an [EXEC] key, and the tool compensation
amount is started to be output.