13
13.2 Diagnosis Information (DGN) List
778
#7
#6 #5 #4 #3 #2 #1 #0
438DGN
Information about communication errors for spindle serial control (third and
fourth spindles).
For contents, see the descriptions about DGN408.
#7
#6 #5 #4 #3 #2 #1 #0
439DGN
SPE S4E S3E SHE
SHE Indicates the state of the serial communication module (third and
fourth spindles) on the CNC side as follows:
0: Normal
1: Abnormal
S3E 0: The third spindle was started normally under spindle serial
control.
1: The third spindle was not started normally under spindle serial
control.
S4E 0: The fourth spindle was started normally under spindle serial
control.
1: The fourth spindle was not started normally under spindle serial
control.
SPE Indicates the state of the serial spindle parameter (third and fourth
spindles) for spindle serial control, as follows:
0: The start condition for the spindle unit is satisfied.
1: The start condition for the spindle unit is not satisfied.
440
Third–spindle load meter indication [%]
DGN
441
Third–spindle speedometer indication [min
–1
]
DGN
442
Fourth–spindle load meter indication [%]
DGN
443
Fourth–spindle speedometer indication [min
–1
]
DGN
445
First–spindle position data [Pulse]
DGN
446
Second–spindle position data [Pulse]
DGN
447
Third–spindle position data [Pulse]
DGN
448
Fourth–spindle position data [Pulse]
DGN
NOTE 1 pulse = 360/4096 (_)
This parameter is valid when PRM3117#1 = 1.
To display the position data of a spindle, execute spindle orientation.