7
7.2 Parameter List
294
02008 Tandem control <Axis>
#1 TNOM : Tandem axis setting
#2 VFBA :
Velocity feedback averaging function
invalidated (0)/validated (1)
#3 SPPR : Full preload function invalidated (0)/validated
(1)
#4 SPPC : The motor output torque polarities are as
follows, outputs only the positive polarity to
the main axis, and outputs only the negative
polarity to the sub–axis (0)/outputs only the
negative polarity to the main axis, and
outputs only the positive polarity to the
sub–axis (1)
#5 VCTM : Velocity command tandem control,
invalidated (0)/validated (1)
#6 PFBS : Position feedback according to the direction
of a torque command, not used (0)/used (1)
#7 LAXD : Damping compensation for the sub–axis only
(0)/damping compensation with both the
main axis and sub–axis (1)
Automati-
cally set by
PRM
1817#6
Set the
Main axis
only
Set the
Main axis
only
Set the
Main axis
only
Set the
Main axis
only
Set the
Main axis
only
Set the
Main axis
only
Usually,
set this bit
to 1
02009 Backlash acceleration/deceleration, dummy
function
<Axis>
#0 SERD: Dummy function for the serial pulse coder is
not used (0)/used (1)
#1 IQOB : Effect of voltage saturation in abnormal load
detection invalidated (0)/validated (1)
#2 ADBL : New type backlash acceleration stop function
is ineffective (0)/effective (1)
#6 BLCU : Backlash acceleration stop function in cutting
mode is ineffective (0)/effective (1)
#7 BLST : Backlash acceleration stop function is
ineffective (0)/effective (1)
Only 9066
series
PRM
2200#2
PRM2048,
2087
PRM2066,
2082