7.2 Parameter List
286
01804 VRDY OFF ignore signal
#1 BLC : During circular interpolation by jog feed
(manual circular interpolation function), the
backlash acceleration function is, disabled (0)/
enabled (1)
#4 IVO : When an attempt is made to release an
emergency stop while the VRDY OFF alarm
ignore signal is 1, the emergency stop state is
not released until the VRDY OFF alarm ignore
signal is set to 0 (0)/the emergency stop state
is released (1)
#5 ANA : When an abnormal load is detected for an axis:
movement along all axes is stopped, and a
servo alarm is output (0)/no servo alarm is
output, and movement along only the axes of
the group containing the axis with the
abnormal load is stopped in interlock mode (1)
#6 SAK : When the IGNVRY signal is 1 or the IGNVRYx
signal for each axis is 1, SA is set to 0 (0)/
1 (1).
01805 Torque control command of PMC axis
#1 TQU : If follow–up is not performed by the torque
control command of PMC axis control, the
servo error counter is, updated(0)/not
updated(1)
PRM
1803#4
01815 Position detector <Axis>
#1 OPT : A separate pulse coder is not used (0)/
used (1)
#2 DCL : As a separate position detector, the linear
scale with absolute addressing reference
marks is: not used (0)/used (1)
#3 DCR : As the scale with absolute addressing
reference marks, the linear scale is
used(0)/the rotary encoder is used(1)
#4 APZ : When the absolute position detector is used,
machine position and absolute position
transducer is not corresponding (0)/
corresponding (1)
#5 APC : Position transducer is incremental position
transducer (0)/absolute pulse coder (1)
#6 NRT : When the machine coordinates have passed
the 0–degree value or the machine coordinate
rounding value (360 degrees or PRM1260) on
a rotation axis, reference position updating is,
performed (0)/not performed (1)
(Set this parameter when using a separate
scale that does not hold rotation data.)
PRM
1815#1
PRM1860,
1861
PRM1881
<QG0529 ,
QG1537+
>