17
17.4 Spindle Setting and Tuning Screen
860
D Control input signal
Max.10 signals those are ON are displayed from the following signals:
TLML : Torque limit command (low)
TLMH : Torque limit command (high)
CTH1 : Gear signal 1
CTH2 : Gear signal 2
SRV : Spindle reverse rotation
SFR : Spindle forward rotation
ORCM : Spindle orientation
MEDY : Machine ready
ARST : Alarm reset signal
*ESP : Emergency stop
SPSL : Spindle selection signal
MCFN : Power line switching
SOCN : Soft start/stop
RSL : Output switching request
RCH : Power line state confirm
INDX : Orientation stop pos.
change
ROTA : Rotation direction of
ORCM
NRRO : Short–cut of ORCM
INTG : Speed integral control
signal
DEFM : Referential mode
command
TML5 : Torque limitation
ORAR : Orientation end signal
CHP : Power line switched signal
CFIN : Spindle switch complete
RCHP : Output switch signal
RCFN : Output switch complete
signal
[Reference] Control input signal address for each spindle
First spindle : <
QG0561+
–
QG0585+
>
Second spindle : <
QG0593+
–
QG0617+
>
Third spindle : <
QG1633+
–
QG1657+
>
Fourth spindle : <
QG2129+
–
QG2153+
>
D Control output signals
Max. 10 signals those are ON are displayed from the following signals:
ALM : Alarm signal
SST : Speed zero signal
SDT : Speed detecting signal
SAR : Speed arrival signal
LDT1 : Load detecting signal 1
LDT2 : Load detecting signal 2
[Reference] Control output signal address for each spindle
First spindle : <
IF0361+
–
IF0385+
>
Second spindle : <
IF0393+
–
IF0417+
>
Third spindle : <
IF1345+
–
IF1369+
>
Fourth spindle : <
IF2129+
–
IF2153+
>