11
11.5 Ethernet Option Board
736
[F DEL]
Deletes files from the host computer.
[GET]
Transfers a single file from the host computer to the Fast data server
built–in ATA card.
[MGET]
Transfers two or more files from the host computer to the Fast data
server built–in ATA card. File names can be specified by using wild
cards (*, ?).
[L–GET]
Transfers files from the host computer to the Fast data server built–in
ATA card according to the list file.
[READ]
Inputs files from the host computer to the part program storage memory
of the CNC. This operation is possible only when the data server is in
the FTP mode, the CNC is in the EDIT mode, and a data server is
specified by an I/O device number of the CNC.
[PUNCH]
Outputs files from the part program storage memory of the CNC to the
host computer. This operation is possible only when the data server is
in the FTP mode, the CNC is in the EDIT mode, and a data server is
specified by an I/O device number of the CNC.
With the data server function, the data Items indicated below can be
input/output.
D NC parameter
D Tool offset value
D Custom macro variable
D Workpiece zero point offset value
D Pitch error compensation data
D M code group
D Operation history data
On each screen, a [READ] or [PUNCH] operation is performed.