7. PARAMETERS
307
03111 Adjustment screen, screen switching
#0 SVS : The servo setting screen is displayed (0)/not
display (1)
#1 SPS : The spindle setting screen is not displayed (0)/
displayed (1)
#2 SVP : The synchronization errors displayed on the
spindle adjustment screen is the instant values
(0)/peak hold values (1)
#5 OPM : The operating monitor is not displayed (0)/
displayed (1)
#6 OPS : The speedometer on the operating monitor
screen indicates the spindle motor (0)/speed of
the spindle (1)
#7 NPA : When an alarm is generated, the display shifts
to the alarm screen (0)/does not shift (1)
03112 Wave form diagnosis function (servo waveform
display)
#0 SGD : Generally used graphic display (0)/servo
waveform display (1)
#2 OMH: The history of external operator messages is
not displayed (0)/displayed (1).
#3 EAH : As alarm history information, macro alarm and
external alarm messages are recorded (0)/not
recorded (1).
#5 OPH : The operation history log function is enabled (0)/
disabled (1).
03113 External operator message
#0 MHC : The external operator message history can be
deleted (0)/cannot be deleted (1).
#4 TCH : Cursor movement on the touch panel is
disabled (0)/enabled (1)
#5 DCL : The compensation function for the touch panel
on the display is disabled (0)/enabled (1)
#6 MS0 :
#7 MS1 : .
0
0
1
1
MS1 MS0
Number of
characters
0
1
0
1
255
200
100
50
Number of
history items
8
10
18
32