7
7.2 Parameter List
430
08311 Axis number of the master axis for an axis
subject to synchronous control
T series : Set the axis number (0 to 7) of the
master axis for each axis.
(Example) When the master axis for the
fourth axis is the second axis, set
00, 20, 00, and 00.
M series: Set the axis number (1 to 8) of the
master axis for each axis.
Parameter for
the first axis
Setting
Tens digit Units digit
Master axis for
the second
axis
Master axis for
the first axis
Parameter for
the second
axis
Master axis for
the fourth axis
Master axis for
the third axis
Parameter for
the third axis
Master axis for
the sixth axis
Master axis for
the fifth axis
Master axis for
the eighth axis
Master axis for
the seventh
axis
Parameter for
the fourth axis
<Axis>
08312 Slave axis mirror image setting (100 or more:
Reversed)
<Axis>
T series
08313 Limit of the difference between the amount of
positioning deviation of the master and slave
axes (Synchronous control one pair)
[Detection unit]
M series
ALM213
08314 Allowable error in synchronization error check <Axis>
M series
ALM407
08315 Maximum compensation value for
synchronization (Synchronous control one pair)
[Detection unit]
<Axis>
M series
ALM410
08316 Difference between reference counters for
master and slave axes (Synchronous control
one pair) [Detection unit]
M series
PRM
8302#1
08317 Torque difference alarm detection time
(Synchronous control one pair) [ms]
M series
08318 Detection timer for the limit of the difference
between the positioning deviation of the master
axis and that of the slave axis [8ms]
M series
08323 Maximum allowable difference between master
axis and slave axis positional deviations
[Detection unit]
<Axis>
M series
ALM213
08325 Maximum compensation value for
synchronization [Detection unit]
<Axis>
M series
PRM
8303#7
ALM407