B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 93 -
1534 Tangent direction acceleration (for finishing)
[Input type] Parameter input
[Data type] Realaxis
[Unit of data] mm/sec/sec, inch/sec/sec, degree/sec/sec (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (D)
(When the machine system is metric system, 0.0 - +100000.0. When
the machine system is inch system, machine, 0.0 - +10000.0)
Stores the tangent direction acceleration for the finishing parameter
set. Usually, the acceleration is entered from the HPCC (SETTING)
screen. If a different value needs to be set for an axis, this parameter
must be directly specified. To make the setting effective during
operation, the "SELECT ACTIVE" key must be pressed on the HPCC
(SETTING) screen.
1535 Normal direction acceleration (for finishing)
[Input type] Parameter input
[Data type] Realaxis
[Unit of data] mm/sec/sec, inch/sec/sec, degree/sec/sec (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (D)
(When the machine system is metric system, 0.0 - +100000.0. When
the machine system is inch system, machine, 0.0 - +10000.0)
Stores the normal direction acceleration for the finishing parameter
set. Usually, the acceleration is entered from the HPCC (SETTING)
screen. If a different value needs to be set for an axis, this parameter
must be directly specified. To make the setting effective during
operation, the "SELECT ACTIVE" key must be pressed on the HPCC
(SETTING) screen.
1536 Time required to reach the maximum acceleration of pre-interpolation bell-
shaped acceleration/deceleration (for finishing)
[Input type] Parameter input
[Data type] Integer
[Unit of data] msec
[Valid data range] 0 - 200
Stores the pre-interpolation bell-shaped acceleration/deceleration time
constant for the finishing parameter set. Usually, the time constant is
entered from the HPCC (SETTING) screen. If a different value needs
to be set for an axis, this parameter must be directly specified. To
make the setting effective during operation, the "SELECT ACTIVE"
key must be pressed on the HPCC (SETTING) screen.