B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 89 -
1496 Critical angle in the automatic exact stop check
[Input type] Parameter input
[Data type] Integer
[Unit of data] degree
[Valid data range] 1 - 179
1497 Distance to travel of minute blocks in the automatic exact stop check
[Input type] Parameter input
[Data type] Real
[Unit of data] mm, inch (input unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 0 or positive 9 digit of minimum unit of data (refer to the standard
parameter setting table (B) )
(When the increment system is IS-B, 0.0 - +999999.999)
#7 #6 #5 #4 #3 #2 #1 #0
1517 FCC FNW ATDF LAA ROU MED FIN SET
[Input type] Parameter input
[Data type] Bit
#0 SET Specifies whether the automatic setting function is enabled on the
HPCC (SETTING) screen.
0: Enabled.
1: Disabled.
#1 FIN Specifies whether the automatic tuning function (FINE) is enabled on
the HPCC (SETTING) screen.
0: Enabled.
1: Disabled.
#2 MED Specifies whether the automatic tuning function (MEDIUM) is
enabled on the HPCC (SETTING) screen.
0: Enabled.
1: Disabled.
#3 ROU Specifies whether automatic tuning function (ROUGH) is enabled on
the HPCC (SETTING) screen.
0: Enabled.
1: Disabled.
#4 LAA
Bit related to the enabling and disabling of
acceleration/deceleration before look-ahead interpolation
0: Whether acceleration/deceleration before look-ahead
interpolation is enabled or disabled depends on the
G05.1/G05 command and the state of MBF, bit 6 of
parameter No. 2401.
1: It is assumed that G05.1Q1 is always issued.
When this parameter bit is set to 1, acceleration/deceleration
before look-ahead interpolation is always specified regardless of
the G05.1/G05 command.