B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 141 -
2011 Minimum width of the M, S, T, or B function completion (FIN) signal
[Input type] Parameter input
[Data type] Integer
[Unit of data] msec
[Valid data range] 0 - 32767
Specify the minimum signal width at which the M, S, T, or B function
completion signal (FIN) is assumed to be valid.
M, S, T, B code
MF, SF, TF, BF signal
FIN signal
Shorter than
minimum signal
width, so ignored.
Longer than minimum
signal width, so
recognized.
2012 Output time of the MF, SF, TF, or BF strobe signal
[Input type] Parameter input
[Data type] Integer
[Unit of data] msec
[Valid data range] 0 - 32767
M, S, T, or B code
MF, SF, TF, or BF signal
Delay
Signal width
2014 Time that mode unselected status is ignored
[Input type] Parameter input
[Data type] Integer
[Unit of data] msec
[Valid data range] From 0 through 2000
If parameter 2001 is specified to ignore the mode selection, when all
the mode selection signals are off (MOC in parameter 2001 = 0) , this
parameter enables the previously selected mode to be maintained for
the specified time that mode unselected status is ignored.
Normally, specify the time needed to ignore mode signal chatter.