5427 Number of the farthest bidirectional pitch error compensation point in the
negative direction (in the case of negative-direction movement)
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integeraxis
[Valid data range] From 0 through 1279 (or from 10000 through 11279) or from 0
through 3071 (or from 10000 through 13071) depending on the
number of controlled axes is less than or equal to 10 or greater than
10, respectively.
When using bidirectional pitch error compensation, set the number of
the farthest compensation point in the negative direction in the case of
negative-direction movement.
NOTE
1 In parameter No. 5421, set the number of the
farthest compensation point in the negative direction
in the case of positive-direction movement.
2 No set of compensation data for one axis must
extend from 1279 (or 3071) to 10000.
5428 Pitch error compensation value at the reference position when a movement
is made to the reference position in the direction opposite to the reference
position return direction
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integeraxis
[Unit of data] detection unit
[Valid data range] -32768 - 32767
By using an absolute value, set a pitch error compensation value at the
reference position when a movement is made to the reference position
in the negative direction if the reference position return direction (bit
5 (ZMI) of parameter No. 1006) is positive, or when a movement is
made to the reference position in the positive direction if the reference
position return direction is negative.