4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 224 -
#7 #6 #5 #4 #3 #2 #1 #0
5580 SMT
[Input type] Parameter input
[Data type] Bit
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
#1 SMT The parameters (No. 5591 to No. 5595) for straightness compensation
multiplier:
0: Are effective only for the first move axis when two or more
move axes are set using the same axis number.
1: Are effective for the respective move axes even when two or
more move axes set using the same axis number.
When the straightness compensation function is used, be sure to set
SCMT to 1.
5581 Straightness compensation point number of most negative side of move
axis 1
5582 Straightness compensation point number of most negative side of move
axis 2
5583 Straightness compensation point number of most negative side of move
axis 3
5584 Straightness compensation point number of most negative side of move
axis 4
5585 Straightness compensation point number of most negative side of move
axis 5
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integer
[Valid data range] From 1280 through 1919 or from 3072 through 3711 depending on
the number of controlled axes is less than or equal to 10 or greater
than 10, respectively.
Specify the straightness compensation point number located at the
most negative position for each move axis.