4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 240 -
5843 Number of pulses of the position detector for a Cs contour control axis
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integerspindle
[Unit of data] detection unit
[Valid data range] 1 - 999999
Set the number of pulses of the position detector for a Cs contour
control axis.
5844 Axis number subject to constant surface speed control
[Input type] Parameter input
[Data type] Integerspindle
[Valid data range] 0 - Max axes
Specify the ordinal number of an axis that is subject to constant
surface speed control. If an axis is specified in the program (G96P_) ,
constant surface speed control is applied to the axis.
If no axis is specified in the program (G96P_) , or P0 is specified,
constant surface speed control is applied to the axis set in this
parameter.
NOTE
If 0 is set, the P value programmed with G96P_ is
ignored, and constant surface speed control is always
performed on the X-axis.
5845 Suffix for serial spindle (main spindle) or analog spindle display
[Input type] Parameter input
[Data type] Integerspindle
[Valid data range] 0 - 122
Set a suffix for spindle speed display on a screen such as the position
display screen.
Setting Character used as suffix
0, 32 Blank
1 to 9, 48 to 57 Numeric 0 to 9
65 to 90 Uppercase letter A to Z
97 to 122 Lowercase letter a to z