4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 78 -
CAUTION
1 This parameter is valid only when parameter DIA
(bit 3 of parameter No. 1006) = 1.
2 If a programmable diameter/radius switching is
used, that is, parameter PDC (bit 5 of parameter
No. 1001) = 1, parameter PDA (bit 3 of parameter
No. 1009) usually specifies whether diameter or
radius is to be used. For the PMC axis, however,
parameter NDI and parameter DIA (bit 3 of
parameter No. 1006) are used to determine the
amount of travel and the feedrate. On the other
hand, whether the position display is displayed as
a diameter or radius is determined by parameter
PDA (bit 3 of parameter No. 1009) .
NOTE
This bit is effective only when DIA (bit 3 of
parameter No. 1006) is set to 1.
#7 #6 #5 #4 #3 #2 #1 #0
1406 F1O
[Input type] Parameter input
[Data type] Bit
#0 F1O Specifies whether to enable feedrate override, second feedrate
override, and override cancellation for the feedrates of F codes with a
one-digit number (F1 to F9) .
0: Disable them.
1: Enable them.
NOTE
Rapid traverse override is enabled for the feedrate of
F0, regardless of the setting of this parameter.