B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 143 -
2021 Negative (-) direction command button on the software operator’s panel
[Input type] Parameter input
[Data type] Integeraxis
[Valid data range] 0 - 9
Specify the number of the numeric (arrow) key on the MDI panel
which instructs manual feed in the negative (-) direction on the
software operator’s panel for each axis. The setting of 5 cannot be
used because the numeric key 5 is fixed to the manual rapid traverse
switch.
This parameter can be used for the first to sixth axes. It is ignored for
the seventh and subsequent axes.
Specifying 0 means that the MDI panel does not have any numeric
key that instructs the negative (-) direction.
Example
If 4 is set for the 1st axis:
Numeric key 4 instructs the - direction of the 1st axis.
If 1 is set for the 2nd axis:
Numeric key 1 instructs the - direction of the 2nd axis.
If 2 is set for the 3rd axis:
Numeric key 2 instructs the - direction of the 3rd axis.
2030 Allowable number of digits in an M code
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - 10
Specify the allowable number of digits in an M code.
NOTE
To set the allowable number of digits in an M
code to 10, the use of a minus "-" in an M code
must be disabled.
2031 Allowable number of digits in an S code
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - 10
Specify the allowable number of digits in an S code.
NOTE
To set the allowable number of digits in an S
code to 10, the use of a minus "-" in an S code
must be disabled.