B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 61 -
NOTE
1 When using the electronic gear box (EGB) function
Although EGB and dummy axes do not require
amplifiers, assume that they are connected to dummy
amplifiers. Thus, as the address conversion table
value for an non-existing slave, set the value equal to
the setting of parameter No. 1023 for the EGB axis
minus 1, instead of "40."
2 For a system with 11 or more controlled axes
Parameters Nos.1100 to 1109 and 1110 to 1119 are
also available in addition to these parameters.
Nos.1080 to 1089 : The parameters of the slaves
linked to the first axis card on main board.
Nos.1100 to 1109 : The parameters of the slaves
linked to the second axis card on additional axis
board.
linked to the third axis card on additional axis board.
#7 #6 #5 #4 #3 #2 #1 #0
1090 ASE FMD
[Input type] Parameter input
[Data type] Bit
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
#0 FMD Specify the FSSB setting mode:
0: Automatic setting mode.
When the relationships between axes and amplifiers and other
information are entered from the FSSB setting screen and
automatic setting is performed, parameters Nos. 1023, 1027,
1028, 1080 to 1089, and 1092 to 1097 are automatically
specified.
1: Manual setting mode.
Parameters Nos. 1023,1027,1028, 1080 to 1089, and 1092 to
1097 must be specified manually.
#1 ASE When the FSSB setting mode is the automatic setting mode (bit 0 of
parameter No. 1090 is set to 0) , automatic setting is:
0: Not completed.
1: Completed.
This bit is automatically set to 1 when automatic setting is completed.