4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 48 -
#7 #6 #5 #4 #3 #2 #1 #0
1008 DCL SFD ROT
[Input type] Parameter input
[Data type] Bitaxis
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
#1 ROT
0: Not multiple rotary control axes.
1: Multiple rotary control axes.
#4 SFD Specifies whether to enable the reference position shift function in
reference position return with the grid method.
0: Disable the function.
1: Enable the function.
#7 DCL Specifies whether to use a linear scale having reference marks as a
separate position detector.
0: Do not use a linear scale having reference marks.
1: Use a linear scale having reference marks.
#7 #6 #5 #4 #3 #2 #1 #0
1009 NFF ZND PDA ROL
[Input type] Parameter input
[Data type] Bitaxis
#2 ROL Specifies whether the roll-over function for a rotation axis is
executed.
0: Not executed.
1: Executed.
NOTE
This bit is valid only for a rotation axis.
#3 PDA Specifies whether move commands are specified by means of
diameter or radius programming in the program for each axis.
0: Radius programming
1: Diameter programming
This bit is valid only when the PDC (bit 5 of parameter No. 1001) is
set to "1." It can be changed by specifying G10.9 (for selecting
diameter or radius programming). The DIA bit (bit 3 of parameter
1006) is automatically set to PDA at power-on and reset.
#4 ZND Specifies whether to display the value set on the workpiece reference
position offset setting menu.
0: Display the value.
1: Do not display the value.