4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 354 -
NOTE
4 If the sequence number set in this parameter
appears more than once in the program, operation
stops after the first matching block in the execution
flow is executed.
7682 Minimum positioning angle for an index table indexing axis
[Input type] Parameter input
[Data type] Real
[Unit of data] degree
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 - +999999.999)
Set a minimum positioning angle (angular displacement) for an index
table indexing axis. An angular displacement for positioning
specification must always be an integral multiple of the setting of this
parameter. When 0 is specified, no angular displacement check is
made.
Not only commands but also coordinate system settings and
workpiece origin offsets are checked for a minimum positioning
angle.
7685 Interval in exponential interpolation for a linear axis (span value)
[Input type] Setting input
[Data type] Real
[Unit of data] mm, inch (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 0 - 999999999
When bit 7 (CBK) of parameter No. 7610 is set to 0, set an interval in
exponential interpolation for a linear axis.
#7 #6 #5 #4 #3 #2 #1 #0
7697 TTD WNM ZG2 BEX
[Input type] Setting input
[Data type] Bit
#0 BEX If a tapping mode command (G63) or canned cycle command (except
the rigid tapping cycle command (G84.2) and the rigid reverse tapping
cycle command (G84.3)) is issued, the mode of
acceleration/deceleration before look-ahead interpolation is:
0:
Turned off.
1: Not turned off.