4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 58 -
1043 Series name of the servo program used
NOTE
After specifying this parameter, turn the power off, and
then on again, for the new setting to take effect.
[Input type] Parameter input
[Data type] Integer axis
[Invalid data range] 0 to 8
If using two or more different servo programs, set the last digit of the
series name of the servo program to be used for each axis (n in 90Bn).
For a set of axes whose servo axis numbers (settings of parameter No.
1023) are consecutive such as (1, 2) or (3, 4), set the same value for
this parameter.
Example:
If using servo program 90B0 for controlled axes 1 and 3 (servo axes
1 and 2) and
servo program 90B3 for controlled axes 2 and 4 (servo axes 3 and 4)
Controlled axis
number
Parameter 1023 Servo program
used
Parameter 1043
P
90B0 0
Q
3 90B3 3
R
2 90B0 0
S
4 90B3 3
NOTE
This parameter is required if two or more servo
programs 90B0 or later are to be used. If using only
one servo program, set 0 for this parameter for all
axes.
If the setting for an odd-numbered servo axis differs
from that for the succeeding axis, alarm SV0455 is
issued.
If the servo program specified for this parameter does
not exist in FROM, alarm SV0455 is issued.