B–63380EN/02
4. DESCRIPTION OF PARAMETERS
11
NOTE
1 An input/output device can also be selected using the setting screen. Usually, the setting
screen is used.
2 The specifications (such as the baud rate and the number of stop bits) of the input/output
devices to be connected must be set in the corresponding parameters for each interface
beforehand. (See Section 4.2.) I/O CHANNEL = 0 and I/O CHANNEL = 1 represent
input/output devices connected to RS–232C serial port 1. Separate parameters for the baud
rate, stop bits, and other specifications are provided for each channel.
3 The input/output unit interface may be referred to as the reader/punch interface.
RS–232C serial port 1 and RS–232C serial port 2 are also referred to as channel 1 and channel
2, respectively. The remote buffer interface is also referred to as channel 3.
Mother board
RS–232–C serial port 1
R232–1(JD36A)
RS–232–C serial port 2
R232–2(JD36B)
R422-1(JD6A)
R232-3(JD28A)
Serial communication board
Remote buffer board
I/O CHANNEL=0, 1
(Channel 1)
I/O CHANNEL=2
(Channel 2)
I/O CHANNEL=3
(Channel 3)
I/O CHANNEL=3
(Channel 3)
RS-232-C I/O device
RS-232-C I/O device
RS-232-C I/O device
(when a remote buffer is used)
RS-422 I/O device
(when a remote buffer is used)