B–63380EN/02
4. DESCRIPTION OF PARAMETERS
149
5214
Setting of an allowable rigid tapping synchronization error range
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 0 to 32767
Each of these parameters is used to set an allowable synchronization error
range between a spindle used for rigid tapping and the tapping axis.
If the value set with each parameter is exceeded, servo alarm No.411
(excessive error during movement) for the tapping axis is issued. When 0
is set, a synchronization error check is not made.
5221
Number of spindle gear teeth (first–stage gear)
5222
Number of spindle gear teeth (second–stage gear)
5223
Number of spindle gear teeth (third–stage gear)
[Data type] Word
[Valid data range] 1 to 32767
When an arbitrary gear ratio is used in rigid tapping, each of these
parameters sets the number of teeth of each spindle gear.
NOTE
1 These parameters are enabled when the VGR parameter
(bit 1 of parameter No.5200) is set to 1.
2 When a position coder is attached to the spindle, set the
same value for all of parameters No.5221 through No.5224.
3 When the DMR function of the position coder signal is used
with a serial spindle, set the VGR parameter (bit 1 of
parameter No.5200) to 0, and set these parameters to 0.
5231
Number of position coder gear teeth (first–stage gear)
5232
Number of position coder gear teeth (second–stage gear)
5233
Number of position coder gear teeth (third–stage gear)
[Data type] Word
[Valid data range] 1 to 32767
When an arbitrary gear ratio is used in rigid tapping, each of these
parameters sets the number of teeth of each position coder gear.