4. DESCRIPTION OF PARAMETERS
B–63380EN/02
176
#7
7100
#6 #5
MPX
#4 #3
HCL
#2
IHD
#1
THD
#0
JHD
[Data type] Bit
JHD Manual handle feed in JOG feed mode or incremental feed in the manual
handle feed
0 : Invalid
1 : Valid
When JHD:=0 When JHD:=1
JOG feed
mode
Manual handle
feed mode
JOG feed
mode
Manual handle
feed mode
JOG feed f f
Manual handle feed f f f
Incremental feed f
THD Manual pulse generator in TEACH IN JOG mode
0 : Invalid
1 : Valid
IHD The travel increment for manual handle interrupt is:
0 : Output unit, and acceleration/deceleration after interpolation is
disabled.
1 : Input unit, and acceleration/deceleration after interpolation is
enabled.
HCL The clearing of handle interruption amount display by soft key [CAN]
operation is:
0 : Disabled.
1 : Enabled.
MPX How signals for selecting the travel distance by manual handle feed are
used during manual handle feed
0 : Uses the signals (MP1 and MP2 : G019 #4 and G019 #5) for the first
manual pulse generator as the signals common to the first to fourth
(third for the T series) manual pulse generators.
1: Uses the signals for selecting the travel distance by manual handle feed
that are dedicated to each manual pulse generator.
First manual pulse generator: MP1 and MP2 (G019 #4 and G019
#5)
Second manual pulse generator: MP21 and MP22 (G087 #0 and
G087 #1)
Third manual pulse generator: MP31 and MP32 (G087 #3 and
G087 #4)
Fourth manual pulse generator: MP41 and MP42 (G087 #6 and
G087 #7)
4.26
PARAMETERS OF
MANUAL HANDLE
FEED, HANDLE
INTERRUPTION AND
HANDLE FEED IN
TOOL AXIAL
DIRECTION