4. DESCRIPTION OF PARAMETERS
B–63380EN/02
28
#7
1201
#6 #5
AWK
#4 #3 #2
ZCL
#1
ZPI
ZPI
#0
ZPR
ZPR
[Data type] Bit
ZPR Automatic setting of a coordinate system when the manual reference
position return is performed
0 : Not set automatically
1 : Set automatically
This bit is ineffective, when a workpiece coordinate system option is
provided, however.
NOTE
ZPR is valid when the workpiece coordinate system option
is not used. When this option is used, however, manual
reference position return always results in a workpiece
coordinate system being established based on the
workpiece origin offsets (parameters No. 1220 to 1226),
regardless of the setting of this parameter. Set 1 when an
absolute–position detector is to be used.
ZPI Coordinates at the reference position when a coordinate system is set
automatically
0 : Value set in parameter No.1250 is used.
1 : For input in mm, the value set in parameter 1250 is used, or for input in
inches, the value set in parameter No.1251 is used.
This bit is ineffective, when a workpiece coordinate system option is
provided, however.
ZCL Local coordinate system when the manual reference position return is
performed
0 : The local coordinate system is not canceled.
1 : The local coordinate system is canceled.
AWK When the workpiece zero point offset value is changed
0 : The absolute position display changed when the next bufforing block
is performed.
1 : The absolute position display is changed immediately.
Changed value is valid ofter baffering the next block.
WZR Upon reset, the workpiece coordinate system is:
0 : Not returned to that specified with G54
1 : Returned to that specified with G54
4.5
PARAMETERS OF
COORDINATES