4. DESCRIPTION OF PARAMETERS
B–63380EN/02
190
8010
Selection of the DI/DO group for each axis controlled by the PMC
[Data type] Byte axis
[Valid data range] 1 to 4
Specify the DI/DO group to be used to specify a command for each
PMC–controlled axis.
Value Description
1 DI/DO group A (G142 to G153) is used.
2 DI/DO group B (G154 to G165) is used.
3 DI/DO group C (G166 to G177) is used.
4 DI/DO group D (G178 to G189) is used.
8022
Upper–limit rate of feed per revolution during PMC axis control
[Data type] Word
Valid data range
Increment system Unit data
IS–B IS–C
Millimeter machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Rotation axis 1 deg/min 6 to 15000 6 to 12000
This parameter sets the upper limit rate of feed per revolution during PMC
axis control.
NOTE
The upper limit specified for the first axis is valid for all axes.
The specifications for the second and subsequent axes are
ignored.
8028
Linear acceleration/deceleration time constant for speed commands for PMC axis control
[Data type] Word axis
[Unit of data] ms/1000 min
–1
[Valid data range] 0 to 32767
This parameter sets the time required for the servo motor rotation speed
to increase or decrease by 1000 min
–1
, for each axis, as a linear
acceleration/deceleration time constant for speed commands for PMC
axis control.
NOTE
If this parameter is set to 0, acceleration/deceleration
control is not applied.
[Unit of data]
[Valid data range]