B–63380EN/02
4. DESCRIPTION OF PARAMETERS
89
#7
3109
#6 #5
RHD
RHD
#4 #3 #2
IKY
IKY
#1
DWT
#0
[Data type] Bit
DWT Characters G and W in the display of tool wear/geometry compensation
amount
0 : The characters are displayed at the left of each number.
1 : The characters are not displayed.
IKY On the tool offset screen and workpiece shift screen (T series), soft key
[INPUT] is:
0 : Displayed.
1 : Not displayed.
RHD When a manual handle interrupt is generated, the relative position display is:
0 : Not updated.
1 : Updated.
NOTE
This parameter is enabled when the INH parameter (bit 2 of
parameter No.7100) is 1.
#7
3110
#6 #5 #4 #3 #2
AHC
#1 #0
[Data type] Bit
AHC Alarm message history data:
0 : Can be cleared.
1 : Can not be cleared
(Such data can be cleared using the [CLEAR] soft key.)
#7
NPA3111
#6
OPS
#5
OPM
#4 #3 #2
SVP
#1
SPS
#0
SVS
[Data type] Bit
SVS Servo tuning screen
0 : Not displayed
1 : Displayed
SPS Spindle tuning screen
0 : Not displayed
1 : Displayed
SVP Synchronization errors displayed on the spindle tuning screen
0 : Instantaneous values are displayed.
1 : Peak–hold values are displayed.
OPM Operating monitor
0 : Not displayed
1 : Displayed
OPS The speedometer on the operating monitor screen indicates:
0 : Spindle motor speed
1 : Spindle speed