C.PARAMTER LIST B-70254EN/01
- 60 -
SPB
0: Outputs a beam in skip operation.
1: Outputs no beam in skip operation.
EDG
0: Turns the beam off when switching the assist gas during edge
machining.
1: Does not turn the beam off when switching the assist gas during
edge machining.
ECH
0: Does not clear the active E number upon reset.
1: Clears the active E number upon reset.
CWY
0: A CO
2
laser oscillator is used.
1: A CW-YAG laser oscillator is used.
#7 #6 #5 #4 #3 #2 #1 #0
15005 DLY ITR GNS BPV TTD INB
Data type: Bit
INB
0: Stops beam output upon completion of pulse distribution.
1: Stops beam output upon completion of in-position check.
TTD
0: Each laser power supply drives only one discharge tube.
1: Each laser power supply drives two discharge tubes.
BPV
0: Opens the bypass valve during power calibration.
1: Closes the bypass valve during power calibration.
GNS
0: Stops the assist gas output during assist gas switching by the
assist gas direct command. (standard)
1: Does not stop assist gas output during assist gas switching by the
assist gas direct command.
ITR
0: Disables the tracing control interlock signal (G227#6 *TRIL).
1: Enables the tracing control interlock signal (G227#6 *TRIL).
DLY
0: Disables the beam output condition delay function.
1: Enables the beam output condition delay function.
#7 #6 #5 #4 #3 #2 #1 #0
15006 PCN PCL PIN TRM NCC
Data type: Bit
NCC
0: Displays the processing condition setting screen.
1: Does not display the processing condition setting screen.